06-02-2013, 06:54 PM
Ok I installed a new temp sensor from Harvey.
Works great, but I notice an issue. I've tried to use the Eagle sensors that were already installed in my engine from the vendor who installed the motor.
But my gauge always went needle up.
So I installed the DeLorean sensor and wired it up to the gauge. When I'm driving it shows pretty close to what the laptop and heat detector show. Usually about 190-215. 215 fans kick on and the car runs nicely at 190.
But randomly the gauge will jump to 260 or 240 and sit there. If I give it gas it drops down to where it's suppose to, sometimes it seems like it gets stuck. But when the gauge does this the other sensors reading coolant are reading 190-215.

What would be the best way to find out what's going on?
I checked the connection at the sensor, that's good.

Thanks!
Darryl

Bitsyncmaster
06-02-2013, 07:02 PM
Is your volt gauge behaving when the temp gauge jumps? Acts like you have an alternator issue. Also I think John sells an otterstat that kicks the fans on at a lower temp. I like the fans going on sooner.

DMC5180
06-02-2013, 08:52 PM
Your gauge is losing the signal from the sender (going open) if the needle jumps too 12:00 position. Just going too 240-260 may mean you have air pockets in the cooling system.

Clean ALL connections on the flexible Circuit Board on the back of the Instrument cluster. Remove the gauge Pal nuts clean and reinstall snug only.
Verify traces on the PCB with an Ohm meter they should be 0.09 or less. Another possible place to look for the intermittent connection is the BH connector under the coil cover.

Mydmc5898
06-02-2013, 10:02 PM
The volt gauge seems to be working ok, it looks like it reads a bit low though at times.
But it seems to do that regardless when the temp sensor acts up. I was thinking maybe that set was just dying as well.

I unplugged and cleaned the connections at the coil cover, and now that you mentioned about air pockets, when I shut the car off I have a long hose attached to the overflow and instead of running behind the lights, I have it running down along the frame. Once in awhile I find spilt coolant there. When I check my level it's still the same level as far as I can see.
When we did a frame restore on it, it acted up before and after we refilled the coolant.
But it does go to 260, usually the needle ends right before it touches 260., never quiet 12o'clock though.
I was going to try the contacts on the back of the gauges as well next.

Thanks,
Darryl

Also I believe I'm using Harvey's otterstat, I could be wrong though.

Ron
06-03-2013, 11:18 AM
This could easily be the ground for the gauge. The gauge compares its ground to the ground coming from the sensor wire. If the gauges ground is weak, it will read high...

I'd try reseating the cluster connections feeding it and checking/cleaning the grounds.

Mydmc5898
06-13-2013, 01:00 PM
I pulled the cluster out and the backside looks brand new.
I checked all the wires to see if they are right and clean and everything is.

I've noticed two issues that have come up.
The volt gauge is off. My computer reads about 14.5-7 and the gauge is reading lower than 13.
Also the door ajar light is on.
I don't have the wires connected to the switch on the door sills.
But the light was coming on randomly, not the doors or interior lights, just the dash light.
Mater of fact the interior lights recently stopped working too.
I checked the fuses and bulbs, but they are good.

Where does the dash ground to? Maybe I should just check that next?
I know my front end was a mess but maybe the wire is just bad too.
Thanks
Darryl