I hooked up one of these to my active load last night and calibrated it to output 5V with a 5Amp draw. I couldn't do too much more because my bench power supply maxed out with 14V @ 2Amps which produced ~ 5V @ 5Amps from the buck converter. That's 89% efficiency. Right?
-
Senior Member

Originally Posted by
jgarland79
http://www.ebay.com/itm/181849944119
I hooked up one of these to my active load last night and calibrated it to output 5V with a 5Amp draw. I couldn't do too much more because my bench power supply maxed out with 14V @ 2Amps which produced ~ 5V @ 5Amps from the buck converter. That's 89% efficiency. Right?
Yes that looks correct. 28 watts input, 25 watts output.
Most switching regulators run around 90%. When the currents go higher you start seeing more losses with the wiring and circuit board trace voltage drop adding to the inefficiency. Also the switching may throw your amp and volt gauge readings off a little. You would need true RMS meters to get very accurate readings.
-
Senior Member
This kind of reminds me of Mercedes new autonomous car with the LED matrix in the back that lets a car behind know that someone in front of you in crossing by using an animation of left to right or right to left vertical bars.