I swapped in a 90" belt in my work today, and the voltmeter stayed a lot higher at idle even with the A/C running (which drags my idle down since I have a carb and no kickdown for the A/C at the moment). Still wish I'd known this a year ago... :/
I swapped in a 90" belt in my work today, and the voltmeter stayed a lot higher at idle even with the A/C running (which drags my idle down since I have a carb and no kickdown for the A/C at the moment). Still wish I'd known this a year ago... :/
Location: Edmonton, Alberta
Posts: 22
My VIN: 06683
Club(s): (TXDMC)
Hello Everyone,
So I hammered in about 3 separate new ground cables into my Car yesterday. I bridged the A/C Compressor to the block, the block to the frame, and the block to the negative battery cable direct.
Unfortunately, the problem persists as before. The battery light flashes briefly when the A/C Clutch disengages. I feel confident in saying that this is not a ground issue. Which leds to the question, what is causing this electrical spike by the A/C Clutch? Could the internal compressor wiring be faulty?
Thanks,
Posts: 1,068
Posts: 1,315
My VIN: 03238 Grey & Black Hybrid - Auto - work in progress Former owner 10902 - Universal 93 Raffle Car
I have the same problem as Regulus on one of the two cars.
This car is an automatic, 2.5 year old Houston alternator. Hervey replacement compressor, Hervey fain fail fix, low current fans, original untouched starter...
I concur that it seems to be the compressor turning off - don't think its the fans because the engine should be warm enough to keep them on.
Regulus, your a lot further down the road checking for a solution, anything you want me to check on my end?
Tom
When the AC cycles, the fans cycle at the same time unless you have a fan controller that delays the fans. So maybe it's the fans causing the flashing light and not the compressor clutch.
Location: Edmonton, Alberta
Posts: 22
My VIN: 06683
Club(s): (TXDMC)
I thought that too, but once I fooled around thinking the problem may have been my Joe Cool. When I three way jumpered the fans, I did it wrong and totally eliminated power to the fans. The light flash problem happened when the compressor kicked off again, this time with no fan at all.
I'm going to put an inline capacitor on the clutch line. Hopefully that evens out the power spike. Right now I'm just looking around for a Capacitor that will take that much amperage.
Thanks
Posts: 1,315
My VIN: 03238 Grey & Black Hybrid - Auto - work in progress Former owner 10902 - Universal 93 Raffle Car
And I've observed mine happening when the engine is at full operating temperature, so I presume the otterstat is closed and the fans are operating full time anyway. Mind you I'm driving so I can't tell if they are running for sure. I'll confirm it later today here in the garage...
While may car has been off the road for about 6 months, this problem began a year ago when it was still being driven regularly . As soon as I started using the AC yesterday it started again.
I further tested it last night by observing that the light would flash every 30 seconds or so. I then turned off the AC and it absolutely stopped, but the engine temp did not start to come down, so I presume the fans stayed on. Drove about 5 minutes with no ac and no flashes. I then turned the AC back on and after about 20 seconds the first flash occurred again.
The Joe Cool will delay the fans anyway.
Any capacitor will work. Normally it's just to suppress electrical noise by slowing the rise and fall times of the current changing in the inductive load.
Use a capacitor with 25 volts or greater rating. Value of 0.5 to 1.0 uf is best for noise but larger may help with the flashing. I don't think that will fix it but can't hurt to try.
Posts: 1,315
My VIN: 03238 Grey & Black Hybrid - Auto - work in progress Former owner 10902 - Universal 93 Raffle Car
I just went to see if installing my fanzilla would do anything to help, and I realized that my blue relay base has been cut out and the wires taped off. I did not have Johns fain fail installed, just a relay in the fan base...
I think i have a spare relay base, so I'm going to start by wiring a fan fail base back in, and then try the fanzilla...
Posts: 1,315
My VIN: 03238 Grey & Black Hybrid - Auto - work in progress Former owner 10902 - Universal 93 Raffle Car
Okay, I wired in a socket for the missing blue socket. The PO had cut it out and taped brown orange output from the circuit breaker directly to both black/green fan wires. Similar in theory to Johns fan fix jumper, except un-fused.
The new socket isn't blue, nor is the orientation correct for the ground pin at the bottom, but neither fanzilla nor Johns products use that pin, so its installed for now to let me keep testing.
So with a properly working fanzilla and two low amperage fans, the light still comes on intermittently when the compressor shuts off.
I'll try to find and test the diode. Per the updated wiring diagrams hosted on this site that is at the point where the black/orange wire coming out of the fan relay (not fan fail) connects to the pink wire running out to the compressor. I'm guessing that's where the main wiring bundle routes under the fuse box, and then turns to the rear of the car, at the most inboard point of that bundle.
Is there a part number for the diode? I can only find the 1 amp and 3 amp diodes... Is this a 3 amp?