FRAMING JOHN DELOREAN - ON VOD
www.framingjohndeloreanfilm.com
-
Administrator

Originally Posted by
DPI JOSH
The CO adjustment screw which you have turned all the way counter clock wise does not control the flow of fuel off idle.
Not that it is his problem, but if you turn the screw to where it raises the plunger at idle, the plunger will be higher throughout the arms travel...???
======
At this point, I would pull a few injectors, put them a jar and turn the screw clockwise (being careful not to push the plate down) until they just started to spray and back it off until they just quit. Then put it all back together and set the CO with a dwell meter per manual.