Quote Originally Posted by Farrar View Post
So what's wrong with the breaker -- apart from the fact that it's in the wrong place in the circuit? Is it just redundant with the fuses in place, so getting rid of it saves clutter, or is there another reason? I'm curious as I am still running with the breaker in place.

Farrar
It is not only redundant but if one fan has an open circuit then the other fan is now "fused" with 40 amps. It saves clutter....YES YES YES. It also adds about 6 foot of wire in the harness. The replacement jumper is 4 inches long.