Here is the data of how the fan motor heats. So the hotter they get, the less CFM you get.
TOBY temperature data
This data was taken with one fan mounted on the OEM shroud. The thermo couple was taped to the back of the motor in a glob of heat sink compound. Looks like I need a better mounting of the thermo couple since when I pushed it to contact the motor my temp readings when up.
Current of the motor decreased when hot because the copper wire resistance goes up with increased temp. The temp and current stabilize when the motor surface area can dissipate any additional heat generated by the input power.
Just goes to show how test data can be skewed. Example: One person comparing fan current is so dependent on how long he ran the test and the room ambient temp.
I could see the advantage to mounting the fans on the front side of the AC/Rad unit to keep the fan motors running cooler and give more CFM and longer life.
Last edited by Bitsyncmaster; 10-21-2012 at 05:35 AM.