    My VIN:    897 5 spd,

    I thought the engineer's comment that the fans were changed at the last minute was the interesting part. Changing to higher load fans explains a lot with regard that whole electrical circuit (breakers, connectors, controls, etc).

    Design flaw ... Hmmm...I can't get to that conclusion. I don't recall late 70's car technology being all that great in almost any regard. And yes we now know better ways to do a lot more things. For that matter, how many cars of that vintage are still running or look as good. Most are compressed into a 2 foot cube by now.

    Quote Originally Posted by Elvis View Post
    Attached is the schematic I drew lightyears ago.
    Thanks for the schematic. It is much better than my drawing. I searched for a schematic but with no luck. It may have been lost with dmctalk.com. When I started this I mostly wanted to document the design and understand how it works. It is an "interesting" circuit/approach. Two coils cancelling each other out in normal operation and closing a reed relay when a fan fails.

    The engineer's comments were interesting.

  2. #12
    Administrator Ron's Avatar
    Join Date:  Jun 2011

    Location:  North GA

    Posts:    6,200

    Club(s):   (SEDOC) (DCUK)

    The reed switch/relay was almost half a century old when the De Lorean was made...

    I think Elvis was talking about a flaw in the "our" implementation, not in general.

  3. #13
    DeLorean Owner Since 2006
    Join Date:  May 2011

    Location:  Waukesha, WI

    Posts:    1,181

    My VIN:    3676

    Club(s):   (DMWC) (DCUK)

    Quote Originally Posted by Farrar View Post
    It's not like the DeLorean's water pump will fail without warning...
    Mine did, actually. I had just left DMCMW for some fairly simple fine-tuning of the Stage II setup they had just installed for me and was on my way to an Anime convention. The car sensed my nerdyness and the pulley on the water pump wouldn't have any part of it and backed off; the belt disconnected and, since the cooling fans had been running due to the stop-and-go traffic I had been stuck in, the car overheated. I was with my soon-to-be ex-girlfriend at the time, so that made things even worse.

  4. #14
    Tweedledumber DCUK Martin's Avatar
    Join Date:  May 2011

    Location:  DeLorean Cars, UK

    Posts:    593

    That's a rare failure, and not really a "fault" in the cooling system (ie one that'd be fixed with bigger radiator fans!)

    Bad luck with that one, hope your engine survived!
    Martin Gutkowski
    -------------
    Very part time DeLoreaner...

  5. #15
    Senior Member nkemp's Avatar
    Join Date:  Jun 2011

    Location:  Buffalo MN

    Posts:    760

    My VIN:    897 5 spd,

    Let's remember that the original problem with the D's cooling system was that it did not come with a method of automatically bleeding the air from the cooling system. Mine got pretty hot one time due to an air bubble in the thermostat housing. When I tried loosening the bleeder it was frozen to the housing. Once I installed the bypass, it runs cooler than normal (likely due to bypassing the thermostat with just enough flow to keep the temp down... I've been meaning to restrict the flow).

    Maybe the original cooling issues he mentions were related to air in the system....Or maybe not... it could have been a function of the early prototype designs. We may never know.

  6. #16
    DeLorean Owner Since 2006
    Join Date:  May 2011

    Location:  Waukesha, WI

    Posts:    1,181

    My VIN:    3676

    Club(s):   (DMWC) (DCUK)

    Quote Originally Posted by DCUK Martin View Post
    That's a rare failure, and not really a "fault" in the cooling system (ie one that'd be fixed with bigger radiator fans!)

    Bad luck with that one, hope your engine survived!
    I know it's a rare failure, thankfully. It's also not something I'd consider a design flaw with the car; perhaps the manner in which the water pump was constructed, but nothing else.

    So far, my car's had about 15,000 miles of problem-free driving ever since.

  7. #17
    Tweedledumber DCUK Martin's Avatar
    Join Date:  May 2011

    Location:  DeLorean Cars, UK

    Posts:    593

    Quote Originally Posted by nkemp View Post
    Let's remember that the original problem with the D's cooling system was that it did not come with a method of automatically bleeding the air from the cooling system.
    Is it? I believe most cars have manual bleed points.

    The Alpine GTA has a bleed on the main hose exiting from the stat so it performs exactly like our "self bleed kits".
    Martin Gutkowski
    -------------
    Very part time DeLoreaner...

  8. #18
    Senior Member
    Join Date:  May 2011

    Location:  Northern NJ

    Posts:    8,825

    My VIN:    10757 1st place Concourse 1998

    Many cars have bleed points. The biggest problem is once the system starts to leak you have to continually bleed the system and fill it. If you do not bleed it and keep it full eventually it can get so low that even if you fill it (and do not bleed the air out) the system can become "airbound" and no longer pump coolant. Small quantities of air can "self-bleed" out of the system. On the Delorean, with all of the plumbing to get the coolant from the back of the car to the front and back again, there are several places for air to collect and a lot of potential leaks. Especially if the car is not maintained.