The firmware was legit corrupt, so you can't fully hold the device responsible for what happens when booting up in a random state. I suspect it booted far enough to engage the pump and purge the injectors and then crash. That suggests that firmware should self-checksum its startup routine and halt on failure.
And, if the firmware loader first executed a program that resets outputs to low before starting a flash, that would have prevented a lot of mess too.
All due to leaving keys in ignition and on all night. I can't recall what captured my attention after getting home causing me to forget my keys, but I know what captured it for 4+ hours the next day!
Mind did this until I fixed the wiring. It seemed to work but slowly unscrewed itself. I hooked it up per (what I thought was) the correct way in the megasquirt manual. In the end I just randomized the wires until it started behaving normally during the test mode. MS3 has a mode where it just cycles in and out repeatedly which was a very fast way to get it straight!