FRAMING JOHN DELOREAN - ON VOD www.framingjohndeloreanfilm.com
Page 1 of 2 1 2 LastLast
Results 1 to 10 of 11

Thread: Leak at Otterstat

  1. #1
    Senior Member
    Join Date:  May 2011

    Location:  Houston

    Posts:    709

    My VIN:    16113

    Club(s):   (SCDC) (DCUK)

    Leak at Otterstat

    Ok, last year when it got cold my car started leaking at the otterstat. Thinking that perhaps the rubber was getting old (the otterstat being 5 years old) I bought a new one, place a sealant around it put it back in the hole. I have both the clip and a zip tie to hold it in place. A few days ago whe nA cold front came through (cold by Texas standards) the thing is leaking again. What gives? I never had an issue until last year.

  2. #2
    Senior Member
    Join Date:  May 2011

    Location:  Northern NJ

    Posts:    8,825

    My VIN:    10757 1st place Concourse 1998

    You do not put ANYTHING on the rubber seal for the otterstadt switch. If you have to you can lubricate it with some coolant to install it. I can't explain why but ANY sealer will cause the rubber seal to leak. Also before installing make sure there is no burr or scratch that can damage the rubber seal. The clip and/or strap tie is only to prevent the switch from popping out, it does nothing to seal the system.
    David Teitelbaum

  3. #3
    Senior Member Bitsyncmaster's Avatar
    Join Date:  May 2011

    Location:  Leonardtown, MD

    Posts:    9,649

    My VIN:    03572

    I used a sealer when I replaced the seal about 5 years ago and has been leak free since.
    Dave M vin 03572
    http://dm-eng.weebly.com/

  4. #4
    Senior Member
    Join Date:  May 2011

    Location:  Northern NJ

    Posts:    8,825

    My VIN:    10757 1st place Concourse 1998

    When I first got my car I did the whole cooling system. I used a smear of silicone sealer on the otterstadt seal. In less than a week it split wide open. It was the orange rubbery silicone type materiel. It did not like the silicone sealer AT ALL!
    David Teitelbaum

  5. #5
    Senior Member Bitsyncmaster's Avatar
    Join Date:  May 2011

    Location:  Leonardtown, MD

    Posts:    9,649

    My VIN:    03572

    Quote Originally Posted by David T View Post
    When I first got my car I did the whole cooling system. I used a smear of silicone sealer on the otterstadt seal. In less than a week it split wide open. It was the orange rubbery silicone type materiel. It did not like the silicone sealer AT ALL!
    David Teitelbaum
    It's the silicone sealer that's the problem. I tried that on the heater hose and it would not seal. I use permatex #2 most always when I need any sealer. Coolant hoses I don't use anything and just use the best hose clamps I can get.
    Dave M vin 03572
    http://dm-eng.weebly.com/

  6. #6
    Senior Member
    Join Date:  May 2011

    Location:  Northern NJ

    Posts:    8,825

    My VIN:    10757 1st place Concourse 1998

    Well, after destroying the seal I tried it "dry" and have not had any problems since and I have done several that way. I used to use Permatex on the hoses but once you use it you can't remove the hose unless you cut it off so now I use a little anti-freeze to lubricate it so I can slip the hose on easier. Make sure the end you are putting the hose on is clean and use a good hose clamp and you don't have leaks that you need to use Permatex (or silicone sealer).
    David Teitelbaum

  7. #7
    Senior Member
    Join Date:  May 2011

    Location:  Houston

    Posts:    709

    My VIN:    16113

    Club(s):   (SCDC) (DCUK)

    We're suppose to get another cold front come through later this week (probably drop the temps down to the 50's). Anyway I'll see if it starts leaking again.

    The verdict so far in this debate is: put sealant on - don't put sealant on. Any other opinions?

    What I can't quite figure out is why, after two otterstats, it's still leaking when it gets cold. I haven't looked at it closely yet this time around. I think I better make sure it's not coming from the hose connection nearby and dripping off the otterstat.

  8. #8
    "Former Delorean owning Guru" Spittybug's Avatar
    Join Date:  Jun 2011

    Location:  Hill Country, TX

    Posts:    1,579

    My VIN:    Formerly 2329

    Quote Originally Posted by lazabby View Post
    I think I better make sure it's not coming from the hose connection nearby and dripping off the otterstat.
    That's my bet. If you want, we can put it up on the lift and take a look......
    Owen
    I.Brew.Beer.

  9. #9
    Senior Member
    Join Date:  May 2011

    Location:  Houston

    Posts:    709

    My VIN:    16113

    Club(s):   (SCDC) (DCUK)

    Quote Originally Posted by Spittybug View Post
    That's my bet. If you want, we can put it up on the lift and take a look......
    And convert the engine to EFI at the same time? Kill two birds with one stone!

  10. #10
    "Former Delorean owning Guru" Spittybug's Avatar
    Join Date:  Jun 2011

    Location:  Hill Country, TX

    Posts:    1,579

    My VIN:    Formerly 2329

    Quote Originally Posted by lazabby View Post
    And convert the engine to EFI at the same time? Kill two birds with one stone!
    Sure! Come on over to the "dark side" and EFI it. Start your own thread in our EFI projects area. Adam and Mike have broken through and are well on their way. First step is to buy the MS unit and build it (or buy one pre built). Then fuel rails, hose, LC1 wide band O2, 6 injectors and a couple of automotive relays. It's just money $$.
    Owen
    I.Brew.Beer.

Page 1 of 2 1 2 LastLast

Tags for this Thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •