I see 2 options: either both blowers have shorted windings/worn bearings or there's some current leakage in wiring. Have you tried running the blower with filtering capacitor disconnected?
2be5c51ac04394b866e5ca7b43dc06b0.jpg
If there's no change, I'd measure the current draw of the blower powered directly from the battery (~30A range meter needed) - should probably be less than 20A if the blower's good.